R820T, RTL2832U SDR USB stick – sensitivity, dynamic range

After looking around in the web, there doesn’t seem to be a whole lot of information out there on the sensitivity and dynamic range of the SDR USB devices, at least not for the type I’m using here. Even the R820T datasheet isn’t all that clear – there are various versions of the R820T, also using different clock frequencies, with 28.8 MHz, being the most popular lately.

Therefore, time for some measurements.

The setup:

(1) HPAK (formerly HP, then Agilent, now Keysight) 8662A Signal Generator as the reference source, 28.800 MHz, 500 mV level.

(2) HPAK 8642B Signal Generator as the test signal source. This has a calibrated output from -140 dBm to +20 dBm, and very clean and free of spurs, and provides up to 2.1 GHz.
Absolute amplitude accuracy is about 1 dB, linearity is considerably better. As it says on the instrument cover – 70 pounds, “two person lift”.
The 8642B is phase locked to the 8662A clock, via a common 10 MHz reference signal. So even with drift, there can’t be any frequency errors getting into the way of our precision testing.

(3) Some well-shielded test cables, RG223/U, and adapters to link to the MCX connector (use a good test cable, but not your best – most of the SMA to MCX connectors aren’t all that precise, and may damage precision SMA connectors).

(4) The modified SDR USB stick, see earlier post.
r820t rtl2832u sdr usb dut

(5) Laptop PC, running SDRSharp. 1.024 MSPS, all automatic gain and frequency adjustments disabled, I/Q correction enabled.

r820t rtl2832u sdr usb test setup

First, the sensitivity check. Tuned the SDR USB to various frequencies, and measured the input power (dBm needed to get a -40 dB reading, at max gain of the SDR USB – 49.6 dB nominal), this is about 15 dB above the noise floor, and still a signal level that is very stable and can be accurately measured. Afterwards, set gain to 0 dB, and increased RF input power until 0 dB reading was obtained – this is the maximum power that can be reasonably fed to the SDR USB (no damage will occur up to +10 dBm; and even +20 dBm doesn’t seem to do much, at least not if only applied for a short time).

Power levels for -40 dB reading at max gain, and 0 dB reading at 0 dB gain:
r820t input sensitivity and max power
Sensitivity is quite constant over a pretty large range, up to 1500 MHz, no problem. Lowest frequency the thing can handle is about 24 Mhz (doesn’t tune any lower). Note that there are some spurious signals present around 28.8 MHz, (internal) ref clock leakage, and its 2nd harmonic.
R820T usb sdr dynamic range and sensitivity

The RF input power (about -130 dBm) to get -40 dB amplitude, at max gain of the SDR USB, this is quite remarkable, and still about 15 dB above the noise floor. So the R820T exhibits very high sensitivity, no doubt.
Here is an estimation of the dynamic range – “useful” because, it is still has some margin for noise. For the full dynamic range, add about 15 dB.
r820t sdr usb dynamic range
About 93 dB (108 dB full range, from noise floor, at 49.6 dB gain, to 0 dB at 0 dB gain).